The YTE MAF560W / MAF560WS Series is a suspended industrial atomization humidifier engineered for wide-area humidity enhancement, evaporative cooling support and high-volume air-assisted mist distribution.
Available in fixed-direction MAF560W and automatic oscillating MAF560WS configurations, the series provides 8,500–14,000 m³/h airflow, 0–20 L/h adjustable atomization output, centrifugal atomization and direct water supply. The MAF560WS provides up to 120° automatic oscillation for wider and more uniform environmental coverage.
HERO CONTENT
Industrial Humidification Without Taking Up Floor Space
Suspended Installation · Up to 14,000 m³/h Airflow · 0–20 L/h Atomization · Up to 120° Oscillation
The YTE MAF560W / MAF560WS Series is designed for facilities that require high-output moisture distribution across medium-to-large areas while keeping floors clear for workers, machinery, livestock, storage and material handling.
Instead of concentrating moisture immediately around the machine, the system uses powerful axial airflow to transport atomized water across the target zone.
This combination makes the MAF560 Series suitable for applications requiring:
- Wide-area humidification
- Dry-air correction
- Evaporative cooling support
- Air movement
- Dust suppression support
- Static-reduction support
- Worker comfort
- Livestock heat-stress support
- Overhead fixed environmental control
TWO AIR DISTRIBUTION OPTIONS
YTE-MAF560W
Fixed-Direction Suspended Atomization Humidifier
The YTE-MAF560W maintains a fixed airflow and mist direction.
It is designed for environments where the target area is known and repeated humidification is required in a specific direction.
Best For
- Fixed production zones
- Warehouse aisles
- Textile production sections
- Livestock zones
- Greenhouse sections
- Fixed work areas
- Continuous directional humidification
- Areas where oscillation is unnecessary
Main Advantages
Stable Direction
Continuous moisture delivery toward a predefined area.
Simpler Coverage Planning
Suitable where the required airflow path does not change.
Overhead Installation
Keeps working and circulation areas clear.
High Air Projection
Available with either 14,000 m³/h or 8,500 m³/h airflow configuration.
YTE-MAF560WS
Automatic Oscillating Suspended Atomization Humidifier
The YTE-MAF560WS adds automatic oscillation to the MAF560 platform.
The fan can sweep through an angle of up to 120°, allowing air and atomized moisture to cover a wider horizontal zone.
Best For
- Wider production areas
- Larger livestock buildings
- Broad greenhouse zones
- Warehouse working areas
- Textile production floors
- Large semi-open spaces
- Areas requiring more uniform moisture distribution
Main Advantages
Up to 120° Oscillation
Expands the effective distribution zone.
More Uniform Humidity Support
Reduces the concentration of mist in one fixed direction.
Broader Environmental Coverage
Suitable where a single fixed airflow path cannot adequately serve the target area.
TWO AIRFLOW CONFIGURATIONS
Both MAF560W and MAF560WS are available in 4-blade and 6-blade configurations.
4-Blade High-Airflow Configuration
Designed for projects requiring stronger airflow, longer projection and faster environmental response.
Main Performance
Input Power: 800 W
Motor Output: 520 W
Motor Speed: 1,400 r/min
Airflow: 14,000 m³/h
Atomization Output: 0–20 L/h adjustable
The source platform identifies the 4-blade configuration as the higher-airflow option.
Recommended When
- The area is large
- Strong airflow is required
- Heat load is high
- Ventilation rate is high
- Faster humidity distribution is required
- Longer mist projection is required
6-Blade Energy-Efficient Configuration
Designed for applications where lower electrical consumption, gentler airflow and long operating cycles are priorities.
Main Performance
Input Power: 340 W
Motor Output: 225 W
Motor Speed: 930 r/min
Airflow: 8,500 m³/h
Atomization Output: 0–20 L/h adjustable
Recommended When
- The coverage area is smaller
- Lower power consumption is preferred
- Continuous operation is expected
- Gentler air movement is required
- Moderate humidification coverage is sufficient
- Energy efficiency is a priority
TECHNICAL SPECIFICATIONS
| Parameter | YTE-MAF560WS 4-Blade | YTE-MAF560WS 6-Blade | YTE-MAF560W 4-Blade | YTE-MAF560W 6-Blade |
|---|---|---|---|---|
| Product Type | Suspended Atomization Humidifier | Suspended Atomization Humidifier | Suspended Atomization Humidifier | Suspended Atomization Humidifier |
| Air Distribution | Oscillating | Oscillating | Fixed | Fixed |
| Input Power | 800 W | 340 W | 800 W | 340 W |
| Motor Output | 520 W | 225 W | 520 W | 225 W |
| Rated Current | 3.75 A | 1.5 A | 3.75 A | 1.5 A |
| Motor Speed | 1,400 r/min | 930 r/min | 1,400 r/min | 930 r/min |
| Airflow Volume | 14,000 m³/h | 8,500 m³/h | 14,000 m³/h | 8,500 m³/h |
| Standard Power Supply | 220 V / 50 Hz | 220 V / 50 Hz | 220 V / 50 Hz | 220 V / 50 Hz |
| Atomization Output | 0–20 L/h | 0–20 L/h | 0–20 L/h | 0–20 L/h |
| Atomization Technology | Centrifugal | Centrifugal | Centrifugal | Centrifugal |
| Oscillation | ≤120° | ≤120° | — | — |
| Reference Coverage | Up to 350 m²* | Up to 250 m²* | Up to 250 m²* | Up to 150 m²* |
| Dimensions | 850 × 580 × 435 mm | 850 × 580 × 435 mm | 700 × 580 × 435 mm | 700 × 580 × 435 mm |
| Net Weight | Approx. 30 kg | Approx. 26 kg | Approx. 25 kg | Approx. 22 kg |
These specifications and stated maximum coverage figures are taken from the existing H560W/H560WS platform. Actual coverage depends on humidity, ceiling height, ventilation, airflow path, heat load, installation position and atomization setting.
IMPORTANT COVERAGE NOTE
The figures above should be presented as maximum reference coverage, not guaranteed engineering coverage.
Actual effective humidification area depends on:
- Starting relative humidity
- Target relative humidity
- Temperature
- Ceiling height
- Air changes per hour
- Fresh-air volume
- Heat load
- Room geometry
- Installation height
- Mist setting
- Fan configuration
- Fixed or oscillating operation
- Number of units
- Water quality
For critical industrial projects, YTE should determine equipment quantity based on space volume and moisture load, not floor area alone.
CENTRIFUGAL ATOMIZATION TECHNOLOGY
High-Output Moisture Generation Without Ultrasonic Transducers
Water enters the atomization assembly and is delivered to a rotating centrifugal atomizer.
The rotating system breaks the water into fine droplets.
The axial fan then carries these droplets into the surrounding environment using high-volume airflow.
This creates a combined system of:
Water Atomization + Air Transport + Moisture Distribution
The platform supports adjustable atomization up to 20 L/h and uses high-volume airflow to spread the resulting mist across the target area.
HOW THE SYSTEM WORKS
1. Water Supply
Water is supplied to the internal water and atomization system.
2. Atomization
The centrifugal atomizer converts the incoming water into fine droplets.
3. High-Volume Airflow
The axial fan generates up to 14,000 m³/h airflow.
4. Air-Assisted Distribution
The mist is transported away from the machine instead of remaining concentrated around the atomizer.
5. Moisture Transfer
A portion of the droplets evaporates into the air and increases environmental moisture content.
6. Environmental Effect
Depending on site conditions, the system can provide:
- Humidity increase
- Evaporative cooling support
- Dust suppression support
- Static reduction support
- Improved environmental comfort
HUMIDIFICATION PERFORMANCE
Designed for Medium-to-Large Areas
The MAF560 Series differs fundamentally from small indoor ultrasonic humidifiers.
Ultrasonic systems are normally suited to controlled rooms with relatively low airflow and precision RH control.
The MAF560 Series is designed for spaces where moisture must be transported across a significantly larger area using airflow.
Typical examples include:
- High-ceiling workshops
- Warehouses
- Textile factories
- Livestock houses
- Greenhouses
- Semi-open buildings
- High-ventilation facilities
EVAPORATIVE COOLING SUPPORT
When atomized droplets evaporate into the surrounding air, the evaporation process absorbs sensible heat.
Under suitable hot, relatively dry and ventilated conditions, approximately 4–8°C localized temperature reduction may be observed on the underlying platform. This is site-dependent and is not a guaranteed room-temperature reduction.
Cooling performance depends particularly on:
- Dry-bulb temperature
- Wet-bulb temperature
- Relative humidity
- Ventilation rate
- Air exchange
- Atomization output
- Installation height
- Airflow direction
- Oscillation
- Heat load
NOT A REFRIGERATION SYSTEM
The MAF560 Series is not mechanical refrigeration.
It does not use:
- Refrigerant
- Compressor
- Condensing coil
- Refrigeration circuit
For applications requiring a guaranteed indoor temperature regardless of outdoor humidity, YTE should recommend an industrial spot cooler, packaged cooling system, AHU or other refrigeration-based solution rather than relying on atomization alone.
DIRECT WATER SUPPLY
Designed for Continuous Industrial Operation
The MAF560 Series uses an external water-supply arrangement rather than relying on a large mobile tank.
This is particularly valuable for suspended installations because the operator does not need to regularly remove or refill a large overhead water reservoir.
Benefits include:
- Longer operating periods
- Stable water supply
- Reduced manual refilling
- Lower labor requirement
- Easier fixed installation
- More consistent mist output
The current source documentation refers to a “5 L direct connection/internal system,” but it explicitly states that this water-system configuration should be confirmed before quotation or installation. For the YTE page, it is safer to state Direct Water Supply / Internal Water System until the production configuration is finalized.
WATER QUALITY
Water quality directly affects atomization stability and maintenance requirements.
Recommended Water
Clean filtered water should be the normal standard.
Depending on local water quality, consider:
- Sediment filtration
- Softened water
- RO-treated water
Poor water quality may cause:
- Mineral deposits
- Scaling
- Atomizer contamination
- Reduced atomization output
- Uneven mist
- Increased maintenance
- Shorter component life
The source platform specifically recommends filtered, softened or RO-treated water where required by local water conditions.
WHY SUSPENDED INSTALLATION MATTERS
Suspended installation is a major functional advantage of the MAF560 Series.
Large industrial and agricultural environments often have limited usable floor space because of:
- Production equipment
- Forklift routes
- Storage racks
- Worker movement
- Livestock movement
- Cleaning requirements
- Safety routes
- Process lines
Installing the humidifier overhead keeps these areas clear while maintaining a consistent environmental-control point.
Suspended installation is particularly suitable where the same area requires moisture every day and there is little need to move the equipment.
FIXED VS OSCILLATING
Choose YTE-MAF560W When
The target zone is fixed.
One direction requires continuous moisture.
The fan is serving a specific aisle, production line, livestock zone or greenhouse section.
Simpler installation is preferred.
The environmental layout does not require sweeping airflow.
Choose YTE-MAF560WS When
A wider area must be covered.
Humidity needs to be distributed more uniformly.
The target zone extends beyond one airflow direction.
Fixed misting may create excessive local wetting.
Multiple work or production zones need coverage.
The automatic oscillation range of up to 120° provides significantly wider distribution than the fixed model.
TYPICAL APPLICATIONS
Textile Manufacturing
Industrial textile processes may require additional humidity to reduce excessively dry air and support static-control strategies.
The MAF560 Series can provide:
- Large-area humidity increase
- Static-reduction support
- Fiber-handling environmental support
- Dust suppression support
- Air circulation
- Worker comfort
For process-critical textile environments with strict RH tolerances, temperature/RH sensors and dedicated control logic should be incorporated.
Manufacturing & Industrial Workshops
Suitable for:
- Assembly factories
- Metalworking facilities
- General manufacturing
- Hot production zones
- Semi-open factories
- Large worker areas
Potential functions include:
- Humidification
- Air movement
- Evaporative cooling support
- Dust suppression support
- Worker comfort
Warehouses & Logistics Centers
The MAF560 Series can support environments experiencing:
- Dry air
- Heat buildup
- Dust
- Large open areas
- Uneven worker comfort
However, mist must not be directed toward moisture-sensitive products, cartons, electronics, electrical equipment or materials that must remain dry.
Livestock & Poultry Facilities
The system can provide:
- Humidity support
- Evaporative cooling
- Air movement
- Dust suppression support
- Heat-stress mitigation
- Wider environmental coverage
Suspended installation allows the equipment to remain above animal movement areas.
System design should consider ventilation rate, sanitation, water quality, animal health, wet-floor risk and electrical protection.
Greenhouses & Horticulture
The MAF560 Series can support:
- Humidity increase
- Dry-zone correction
- Evaporative cooling
- Wide-area mist distribution
- Heat-stress reduction
- Air movement
MAF560W is more suitable for defined greenhouse sections.
MAF560WS is preferable where sweeping distribution across a wider zone is required.
Food Processing Facilities
Possible applications include:
- Work-zone environmental support
- Humidity enhancement
- Evaporative cooling
- General air distribution
Food facilities must evaluate:
- Water quality
- Hygiene requirements
- Cleaning procedures
- Spray direction
- Product exposure
- Local food-safety requirements
Mist should not be directed onto exposed products, food-contact surfaces or moisture-sensitive packaging unless the process has been approved for such use.
STRUCTURAL COMPONENTS
Typical MAF560 Series components include:
- Axial fan housing
- Fan blade assembly
- Front grille
- Rear grille
- Electric motor
- Centrifugal atomizer
- Internal water system
- Water pump
- Float mechanism
- Filter screen
- Water inlet
- Water-flow adjustment
- Drain valve
- Suspension structure
- Oscillation mechanism on MAF560WS
- Operating / oscillation control
The final production configuration should be confirmed according to model, destination market and project requirements.
INSTALLATION GUIDELINES
Before selecting installation positions, confirm:
- Application
- Room dimensions
- Ceiling height
- Existing ventilation
- Starting RH
- Target RH
- Ambient temperature
- Heat load
- Required coverage
- Fixed or oscillating model
- 4-blade or 6-blade configuration
- Installation height
- Structural load capacity
- Water route
- Water pressure
- Water quality
- Electrical supply
- Maintenance clearance
- Mist direction
- Sensitive equipment
- Wet-floor risk
INSTALLATION PRINCIPLES
Install the machine where the generated mist has sufficient space to disperse.
Avoid direct mist discharge toward:
- Electrical cabinets
- Electrical panels
- PLC equipment
- Sensitive electronics
- Moisture-sensitive materials
- Packaging that must remain dry
For the MAF560WS, allow sufficient clearance throughout the complete oscillation range.
Keep maintenance access around:
- Atomizer
- Water system
- Motor
- Filter
- Oscillation system
MULTIPLE-UNIT PROJECTS
Large environments should not be sized by coverage area alone.
For multiple-unit projects, YTE should evaluate:
Space Volume
Length × Width × Height
Moisture Load
Required water addition to move from existing RH to target RH.
Air Exchange
Outdoor-air and exhaust rates can remove added moisture rapidly.
Airflow Interaction
Units should work together rather than opposing each other.
Installation Position
Overlapping mist distribution may create local over-wetting.
Control Strategy
For controlled industrial humidity, the system can be paired with temperature/RH monitoring and automatic control.
MODEL SELECTION TABLE
| Requirement | MAF560W 4-Blade | MAF560W 6-Blade | MAF560WS 4-Blade | MAF560WS 6-Blade |
|---|---|---|---|---|
| Fixed Distribution | Excellent | Excellent | — | — |
| Oscillating Distribution | — | — | Excellent | Excellent |
| Highest Airflow | Excellent | Moderate | Excellent | Moderate |
| Energy Efficiency | Moderate | Excellent | Moderate | Excellent |
| Large Coverage | Very Good | Good | Excellent | Very Good |
| Gentle Airflow | Moderate | Excellent | Moderate | Excellent |
| Continuous Operation | Very Good | Excellent | Very Good | Excellent |
| Wider Mist Distribution | Good | Good | Excellent | Excellent |
APPLICATION LIMITATIONS
The MAF560 Series is intended for:
Industrial humidification
Wide-area atomization
Evaporative cooling support
Air-assisted moisture distribution
Dust suppression support
It should not be positioned as:
- Precision cleanroom humidification
- Laboratory RH control
- Steam humidification
- Precision ultrasonic humidity control
- Mechanical air conditioning
- Refrigeration equipment
For tightly controlled spaces requiring narrow RH tolerances, YTE should use a dedicated humidity-control system with sensors, controllers and appropriately selected humidification technology.
MAINTENANCE
Routine inspection should include:
- Atomization disc
- Water filter
- Water pump
- Water lines
- Fan blade
- Motor
- Fan grille
- Suspension hardware
- Electrical cable
- Mounting points
- Drain system
- Oscillation mechanism on MAF560WS
Maintenance frequency depends on:
- Water hardness
- Water cleanliness
- Daily operating hours
- Dust concentration
- Process contamination
- Environmental conditions
PROJECT & OEM SUPPORT
YTE can support project-specific configurations including:
- Fixed or oscillating selection
- 4-blade or 6-blade configuration
- Voltage configuration
- Plug configuration
- Label customization
- Mounting confirmation
- Water filtration selection
- Installation-layout recommendations
- Multi-unit selection
- Export packaging
- International project supply
Before quotation, customers should provide:
- Country
- Application
- Space dimensions
- Ceiling height
- Ambient temperature
- Existing RH
- Target RH
- Ventilation conditions
- Electrical supply
- Required quantity
- Installation method
- Water quality
FAQ
What is the difference between YTE-MAF560W and YTE-MAF560WS?
The MAF560W is a fixed-direction suspended model.
The MAF560WS provides automatic oscillation of up to 120° for wider and more uniform distribution.
What is the difference between the 4-blade and 6-blade versions?
The 4-blade version is designed for higher airflow, delivering approximately 14,000 m³/h.
The 6-blade version operates at lower power and provides approximately 8,500 m³/h, making it better suited to energy-conscious or gentler-airflow applications.
How much water can the machine atomize?
Atomization output is adjustable from:
0–20 L/h
for all four configurations.
Is it mainly a fan or a humidifier?
The MAF560 Series should be positioned primarily as an industrial atomization humidifier.
The fan is an essential part of the system because high airflow transports the atomized moisture across a larger area.
Can it reduce temperature?
Yes, through evaporative cooling.
Under suitable hot, dry and ventilated conditions, approximately 4–8°C localized cooling may occur, but performance depends on site conditions and is not guaranteed.
Can it replace an air conditioner?
No.
The unit does not use mechanical refrigeration and cannot provide the same controlled temperature performance as an air-conditioning system.
Can it control RH precisely?
Not by itself.
For tighter humidity control, use RH sensors, controllers and an engineered control strategy.
Does it require a water tank?
The product is designed around a direct water supply / internal water system rather than a large mobile tank.
Final water-system configuration should be confirmed for the ordered version.
What water should be used?
Clean filtered water is recommended.
Softened or RO-treated water may be appropriate in hard-water or process-sensitive applications.
Can multiple units be installed together?
Yes.
Large facilities can use multiple units, but installation positions should be engineered according to room geometry, ventilation, target RH and airflow interaction.
[END]