Shop

The YTE MAF560W / MAF560WS Series is a suspended industrial atomization humidifier engineered for wide-area humidity enhancement, evaporative cooling support and high-volume air-assisted mist distribution.

Available in fixed-direction MAF560W and automatic oscillating MAF560WS configurations, the series provides 8,500–14,000 m³/h airflow, 0–20 L/h adjustable atomization output, centrifugal atomization and direct water supply. The MAF560WS provides up to 120° automatic oscillation for wider and more uniform environmental coverage.


HERO CONTENT

Industrial Humidification Without Taking Up Floor Space

Suspended Installation · Up to 14,000 m³/h Airflow · 0–20 L/h Atomization · Up to 120° Oscillation

The YTE MAF560W / MAF560WS Series is designed for facilities that require high-output moisture distribution across medium-to-large areas while keeping floors clear for workers, machinery, livestock, storage and material handling.

Instead of concentrating moisture immediately around the machine, the system uses powerful axial airflow to transport atomized water across the target zone.

This combination makes the MAF560 Series suitable for applications requiring:

  • Wide-area humidification
  • Dry-air correction
  • Evaporative cooling support
  • Air movement
  • Dust suppression support
  • Static-reduction support
  • Worker comfort
  • Livestock heat-stress support
  • Overhead fixed environmental control

TWO AIR DISTRIBUTION OPTIONS

YTE-MAF560W

Fixed-Direction Suspended Atomization Humidifier

The YTE-MAF560W maintains a fixed airflow and mist direction.

It is designed for environments where the target area is known and repeated humidification is required in a specific direction.

Best For

  • Fixed production zones
  • Warehouse aisles
  • Textile production sections
  • Livestock zones
  • Greenhouse sections
  • Fixed work areas
  • Continuous directional humidification
  • Areas where oscillation is unnecessary

Main Advantages

Stable Direction
Continuous moisture delivery toward a predefined area.

Simpler Coverage Planning
Suitable where the required airflow path does not change.

Overhead Installation
Keeps working and circulation areas clear.

High Air Projection
Available with either 14,000 m³/h or 8,500 m³/h airflow configuration.


YTE-MAF560WS

Automatic Oscillating Suspended Atomization Humidifier

The YTE-MAF560WS adds automatic oscillation to the MAF560 platform.

The fan can sweep through an angle of up to 120°, allowing air and atomized moisture to cover a wider horizontal zone.

Best For

  • Wider production areas
  • Larger livestock buildings
  • Broad greenhouse zones
  • Warehouse working areas
  • Textile production floors
  • Large semi-open spaces
  • Areas requiring more uniform moisture distribution

Main Advantages

Up to 120° Oscillation
Expands the effective distribution zone.

More Uniform Humidity Support
Reduces the concentration of mist in one fixed direction.

Broader Environmental Coverage
Suitable where a single fixed airflow path cannot adequately serve the target area.


TWO AIRFLOW CONFIGURATIONS

Both MAF560W and MAF560WS are available in 4-blade and 6-blade configurations.


4-Blade High-Airflow Configuration

Designed for projects requiring stronger airflow, longer projection and faster environmental response.

Main Performance

Input Power: 800 W
Motor Output: 520 W
Motor Speed: 1,400 r/min
Airflow: 14,000 m³/h
Atomization Output: 0–20 L/h adjustable

The source platform identifies the 4-blade configuration as the higher-airflow option.

Recommended When

  • The area is large
  • Strong airflow is required
  • Heat load is high
  • Ventilation rate is high
  • Faster humidity distribution is required
  • Longer mist projection is required

6-Blade Energy-Efficient Configuration

Designed for applications where lower electrical consumption, gentler airflow and long operating cycles are priorities.

Main Performance

Input Power: 340 W
Motor Output: 225 W
Motor Speed: 930 r/min
Airflow: 8,500 m³/h
Atomization Output: 0–20 L/h adjustable

Recommended When

  • The coverage area is smaller
  • Lower power consumption is preferred
  • Continuous operation is expected
  • Gentler air movement is required
  • Moderate humidification coverage is sufficient
  • Energy efficiency is a priority

TECHNICAL SPECIFICATIONS

Parameter YTE-MAF560WS 4-Blade YTE-MAF560WS 6-Blade YTE-MAF560W 4-Blade YTE-MAF560W 6-Blade
Product Type Suspended Atomization Humidifier Suspended Atomization Humidifier Suspended Atomization Humidifier Suspended Atomization Humidifier
Air Distribution Oscillating Oscillating Fixed Fixed
Input Power 800 W 340 W 800 W 340 W
Motor Output 520 W 225 W 520 W 225 W
Rated Current 3.75 A 1.5 A 3.75 A 1.5 A
Motor Speed 1,400 r/min 930 r/min 1,400 r/min 930 r/min
Airflow Volume 14,000 m³/h 8,500 m³/h 14,000 m³/h 8,500 m³/h
Standard Power Supply 220 V / 50 Hz 220 V / 50 Hz 220 V / 50 Hz 220 V / 50 Hz
Atomization Output 0–20 L/h 0–20 L/h 0–20 L/h 0–20 L/h
Atomization Technology Centrifugal Centrifugal Centrifugal Centrifugal
Oscillation ≤120° ≤120° — —
Reference Coverage Up to 350 m²* Up to 250 m²* Up to 250 m²* Up to 150 m²*
Dimensions 850 × 580 × 435 mm 850 × 580 × 435 mm 700 × 580 × 435 mm 700 × 580 × 435 mm
Net Weight Approx. 30 kg Approx. 26 kg Approx. 25 kg Approx. 22 kg

These specifications and stated maximum coverage figures are taken from the existing H560W/H560WS platform. Actual coverage depends on humidity, ceiling height, ventilation, airflow path, heat load, installation position and atomization setting.


IMPORTANT COVERAGE NOTE

The figures above should be presented as maximum reference coverage, not guaranteed engineering coverage.

Actual effective humidification area depends on:

  • Starting relative humidity
  • Target relative humidity
  • Temperature
  • Ceiling height
  • Air changes per hour
  • Fresh-air volume
  • Heat load
  • Room geometry
  • Installation height
  • Mist setting
  • Fan configuration
  • Fixed or oscillating operation
  • Number of units
  • Water quality

For critical industrial projects, YTE should determine equipment quantity based on space volume and moisture load, not floor area alone.


CENTRIFUGAL ATOMIZATION TECHNOLOGY

High-Output Moisture Generation Without Ultrasonic Transducers

Water enters the atomization assembly and is delivered to a rotating centrifugal atomizer.

The rotating system breaks the water into fine droplets.

The axial fan then carries these droplets into the surrounding environment using high-volume airflow.

This creates a combined system of:

Water Atomization + Air Transport + Moisture Distribution

The platform supports adjustable atomization up to 20 L/h and uses high-volume airflow to spread the resulting mist across the target area.


HOW THE SYSTEM WORKS

1. Water Supply

Water is supplied to the internal water and atomization system.

2. Atomization

The centrifugal atomizer converts the incoming water into fine droplets.

3. High-Volume Airflow

The axial fan generates up to 14,000 m³/h airflow.

4. Air-Assisted Distribution

The mist is transported away from the machine instead of remaining concentrated around the atomizer.

5. Moisture Transfer

A portion of the droplets evaporates into the air and increases environmental moisture content.

6. Environmental Effect

Depending on site conditions, the system can provide:

  • Humidity increase
  • Evaporative cooling support
  • Dust suppression support
  • Static reduction support
  • Improved environmental comfort

HUMIDIFICATION PERFORMANCE

Designed for Medium-to-Large Areas

The MAF560 Series differs fundamentally from small indoor ultrasonic humidifiers.

Ultrasonic systems are normally suited to controlled rooms with relatively low airflow and precision RH control.

The MAF560 Series is designed for spaces where moisture must be transported across a significantly larger area using airflow.

Typical examples include:

  • High-ceiling workshops
  • Warehouses
  • Textile factories
  • Livestock houses
  • Greenhouses
  • Semi-open buildings
  • High-ventilation facilities

EVAPORATIVE COOLING SUPPORT

When atomized droplets evaporate into the surrounding air, the evaporation process absorbs sensible heat.

Under suitable hot, relatively dry and ventilated conditions, approximately 4–8°C localized temperature reduction may be observed on the underlying platform. This is site-dependent and is not a guaranteed room-temperature reduction.

Cooling performance depends particularly on:

  • Dry-bulb temperature
  • Wet-bulb temperature
  • Relative humidity
  • Ventilation rate
  • Air exchange
  • Atomization output
  • Installation height
  • Airflow direction
  • Oscillation
  • Heat load

NOT A REFRIGERATION SYSTEM

The MAF560 Series is not mechanical refrigeration.

It does not use:

  • Refrigerant
  • Compressor
  • Condensing coil
  • Refrigeration circuit

For applications requiring a guaranteed indoor temperature regardless of outdoor humidity, YTE should recommend an industrial spot cooler, packaged cooling system, AHU or other refrigeration-based solution rather than relying on atomization alone.


DIRECT WATER SUPPLY

Designed for Continuous Industrial Operation

The MAF560 Series uses an external water-supply arrangement rather than relying on a large mobile tank.

This is particularly valuable for suspended installations because the operator does not need to regularly remove or refill a large overhead water reservoir.

Benefits include:

  • Longer operating periods
  • Stable water supply
  • Reduced manual refilling
  • Lower labor requirement
  • Easier fixed installation
  • More consistent mist output

The current source documentation refers to a “5 L direct connection/internal system,” but it explicitly states that this water-system configuration should be confirmed before quotation or installation. For the YTE page, it is safer to state Direct Water Supply / Internal Water System until the production configuration is finalized.


WATER QUALITY

Water quality directly affects atomization stability and maintenance requirements.

Recommended Water

Clean filtered water should be the normal standard.

Depending on local water quality, consider:

  • Sediment filtration
  • Softened water
  • RO-treated water

Poor water quality may cause:

  • Mineral deposits
  • Scaling
  • Atomizer contamination
  • Reduced atomization output
  • Uneven mist
  • Increased maintenance
  • Shorter component life

The source platform specifically recommends filtered, softened or RO-treated water where required by local water conditions.


WHY SUSPENDED INSTALLATION MATTERS

Suspended installation is a major functional advantage of the MAF560 Series.

Large industrial and agricultural environments often have limited usable floor space because of:

  • Production equipment
  • Forklift routes
  • Storage racks
  • Worker movement
  • Livestock movement
  • Cleaning requirements
  • Safety routes
  • Process lines

Installing the humidifier overhead keeps these areas clear while maintaining a consistent environmental-control point.

Suspended installation is particularly suitable where the same area requires moisture every day and there is little need to move the equipment.


FIXED VS OSCILLATING

Choose YTE-MAF560W When

The target zone is fixed.

One direction requires continuous moisture.

The fan is serving a specific aisle, production line, livestock zone or greenhouse section.

Simpler installation is preferred.

The environmental layout does not require sweeping airflow.


Choose YTE-MAF560WS When

A wider area must be covered.

Humidity needs to be distributed more uniformly.

The target zone extends beyond one airflow direction.

Fixed misting may create excessive local wetting.

Multiple work or production zones need coverage.

The automatic oscillation range of up to 120° provides significantly wider distribution than the fixed model.


TYPICAL APPLICATIONS

Textile Manufacturing

Industrial textile processes may require additional humidity to reduce excessively dry air and support static-control strategies.

The MAF560 Series can provide:

  • Large-area humidity increase
  • Static-reduction support
  • Fiber-handling environmental support
  • Dust suppression support
  • Air circulation
  • Worker comfort

For process-critical textile environments with strict RH tolerances, temperature/RH sensors and dedicated control logic should be incorporated.


Manufacturing & Industrial Workshops

Suitable for:

  • Assembly factories
  • Metalworking facilities
  • General manufacturing
  • Hot production zones
  • Semi-open factories
  • Large worker areas

Potential functions include:

  • Humidification
  • Air movement
  • Evaporative cooling support
  • Dust suppression support
  • Worker comfort

Warehouses & Logistics Centers

The MAF560 Series can support environments experiencing:

  • Dry air
  • Heat buildup
  • Dust
  • Large open areas
  • Uneven worker comfort

However, mist must not be directed toward moisture-sensitive products, cartons, electronics, electrical equipment or materials that must remain dry.


Livestock & Poultry Facilities

The system can provide:

  • Humidity support
  • Evaporative cooling
  • Air movement
  • Dust suppression support
  • Heat-stress mitigation
  • Wider environmental coverage

Suspended installation allows the equipment to remain above animal movement areas.

System design should consider ventilation rate, sanitation, water quality, animal health, wet-floor risk and electrical protection.


Greenhouses & Horticulture

The MAF560 Series can support:

  • Humidity increase
  • Dry-zone correction
  • Evaporative cooling
  • Wide-area mist distribution
  • Heat-stress reduction
  • Air movement

MAF560W is more suitable for defined greenhouse sections.

MAF560WS is preferable where sweeping distribution across a wider zone is required.


Food Processing Facilities

Possible applications include:

  • Work-zone environmental support
  • Humidity enhancement
  • Evaporative cooling
  • General air distribution

Food facilities must evaluate:

  • Water quality
  • Hygiene requirements
  • Cleaning procedures
  • Spray direction
  • Product exposure
  • Local food-safety requirements

Mist should not be directed onto exposed products, food-contact surfaces or moisture-sensitive packaging unless the process has been approved for such use.


STRUCTURAL COMPONENTS

Typical MAF560 Series components include:

  • Axial fan housing
  • Fan blade assembly
  • Front grille
  • Rear grille
  • Electric motor
  • Centrifugal atomizer
  • Internal water system
  • Water pump
  • Float mechanism
  • Filter screen
  • Water inlet
  • Water-flow adjustment
  • Drain valve
  • Suspension structure
  • Oscillation mechanism on MAF560WS
  • Operating / oscillation control

The final production configuration should be confirmed according to model, destination market and project requirements.


INSTALLATION GUIDELINES

Before selecting installation positions, confirm:

  • Application
  • Room dimensions
  • Ceiling height
  • Existing ventilation
  • Starting RH
  • Target RH
  • Ambient temperature
  • Heat load
  • Required coverage
  • Fixed or oscillating model
  • 4-blade or 6-blade configuration
  • Installation height
  • Structural load capacity
  • Water route
  • Water pressure
  • Water quality
  • Electrical supply
  • Maintenance clearance
  • Mist direction
  • Sensitive equipment
  • Wet-floor risk

INSTALLATION PRINCIPLES

Install the machine where the generated mist has sufficient space to disperse.

Avoid direct mist discharge toward:

  • Electrical cabinets
  • Electrical panels
  • PLC equipment
  • Sensitive electronics
  • Moisture-sensitive materials
  • Packaging that must remain dry

For the MAF560WS, allow sufficient clearance throughout the complete oscillation range.

Keep maintenance access around:

  • Atomizer
  • Water system
  • Motor
  • Filter
  • Oscillation system

MULTIPLE-UNIT PROJECTS

Large environments should not be sized by coverage area alone.

For multiple-unit projects, YTE should evaluate:

Space Volume

Length × Width × Height

Moisture Load

Required water addition to move from existing RH to target RH.

Air Exchange

Outdoor-air and exhaust rates can remove added moisture rapidly.

Airflow Interaction

Units should work together rather than opposing each other.

Installation Position

Overlapping mist distribution may create local over-wetting.

Control Strategy

For controlled industrial humidity, the system can be paired with temperature/RH monitoring and automatic control.


MODEL SELECTION TABLE

Requirement MAF560W 4-Blade MAF560W 6-Blade MAF560WS 4-Blade MAF560WS 6-Blade
Fixed Distribution Excellent Excellent — —
Oscillating Distribution — — Excellent Excellent
Highest Airflow Excellent Moderate Excellent Moderate
Energy Efficiency Moderate Excellent Moderate Excellent
Large Coverage Very Good Good Excellent Very Good
Gentle Airflow Moderate Excellent Moderate Excellent
Continuous Operation Very Good Excellent Very Good Excellent
Wider Mist Distribution Good Good Excellent Excellent

APPLICATION LIMITATIONS

The MAF560 Series is intended for:

Industrial humidification
Wide-area atomization
Evaporative cooling support
Air-assisted moisture distribution
Dust suppression support

It should not be positioned as:

  • Precision cleanroom humidification
  • Laboratory RH control
  • Steam humidification
  • Precision ultrasonic humidity control
  • Mechanical air conditioning
  • Refrigeration equipment

For tightly controlled spaces requiring narrow RH tolerances, YTE should use a dedicated humidity-control system with sensors, controllers and appropriately selected humidification technology.


MAINTENANCE

Routine inspection should include:

  • Atomization disc
  • Water filter
  • Water pump
  • Water lines
  • Fan blade
  • Motor
  • Fan grille
  • Suspension hardware
  • Electrical cable
  • Mounting points
  • Drain system
  • Oscillation mechanism on MAF560WS

Maintenance frequency depends on:

  • Water hardness
  • Water cleanliness
  • Daily operating hours
  • Dust concentration
  • Process contamination
  • Environmental conditions

PROJECT & OEM SUPPORT

YTE can support project-specific configurations including:

  • Fixed or oscillating selection
  • 4-blade or 6-blade configuration
  • Voltage configuration
  • Plug configuration
  • Label customization
  • Mounting confirmation
  • Water filtration selection
  • Installation-layout recommendations
  • Multi-unit selection
  • Export packaging
  • International project supply

Before quotation, customers should provide:

  • Country
  • Application
  • Space dimensions
  • Ceiling height
  • Ambient temperature
  • Existing RH
  • Target RH
  • Ventilation conditions
  • Electrical supply
  • Required quantity
  • Installation method
  • Water quality

FAQ

What is the difference between YTE-MAF560W and YTE-MAF560WS?

The MAF560W is a fixed-direction suspended model.

The MAF560WS provides automatic oscillation of up to 120° for wider and more uniform distribution.


What is the difference between the 4-blade and 6-blade versions?

The 4-blade version is designed for higher airflow, delivering approximately 14,000 m³/h.

The 6-blade version operates at lower power and provides approximately 8,500 m³/h, making it better suited to energy-conscious or gentler-airflow applications.


How much water can the machine atomize?

Atomization output is adjustable from:

0–20 L/h

for all four configurations.


Is it mainly a fan or a humidifier?

The MAF560 Series should be positioned primarily as an industrial atomization humidifier.

The fan is an essential part of the system because high airflow transports the atomized moisture across a larger area.


Can it reduce temperature?

Yes, through evaporative cooling.

Under suitable hot, dry and ventilated conditions, approximately 4–8°C localized cooling may occur, but performance depends on site conditions and is not guaranteed.


Can it replace an air conditioner?

No.

The unit does not use mechanical refrigeration and cannot provide the same controlled temperature performance as an air-conditioning system.


Can it control RH precisely?

Not by itself.

For tighter humidity control, use RH sensors, controllers and an engineered control strategy.


Does it require a water tank?

The product is designed around a direct water supply / internal water system rather than a large mobile tank.

Final water-system configuration should be confirmed for the ordered version.


What water should be used?

Clean filtered water is recommended.

Softened or RO-treated water may be appropriate in hard-water or process-sensitive applications.


Can multiple units be installed together?

Yes.

Large facilities can use multiple units, but installation positions should be engineered according to room geometry, ventilation, target RH and airflow interaction.

[END]

WHATSAPP CONSULTATION