Shop

High-Volume Airflow · Evaporative Cooling · Humidification · Environmental Spraying

The YTE MAF560 Series is a heavy-duty mobile atomization fan designed for industrial cooling, humidification, air circulation and compatible environmental spraying applications.

By combining high-volume airflow with centrifugal atomization, the system distributes fine water mist across a wide operating area. As the mist evaporates, it absorbs heat from the surrounding air, providing evaporative cooling while increasing humidity where required.

With a large-capacity water tank, automatic oscillation, adjustable atomization output and independent fan operation, the MAF560 Series is suitable for factories, workshops, warehouses, agriculture, livestock facilities, concrete curing, outdoor work areas and other demanding environments.


Models

YTE-MAF560-H

High-Airflow Version

Designed for applications requiring stronger air movement and wider coverage.

  • Airflow: 14,000 m³/h
  • Motor Speed: 1,400 rpm
  • Input Power: 800 W
  • Atomization Output: 0–20 L/h
  • Recommended Coverage: Up to 350 m²

YTE-MAF560-E

Energy-Efficient Version

Designed for applications where lower energy consumption and quieter, lower-speed operation are preferred.

  • Airflow: 8,500 m³/h
  • Motor Speed: 930 rpm
  • Input Power: 340 W
  • Atomization Output: 0–20 L/h
  • Recommended Coverage: Up to 250 m²

One Mobile System. Multiple Functions.

Evaporative Cooling

Fine atomized water is introduced into the high-volume airflow. As the water evaporates, it absorbs sensible heat from the surrounding air.

This makes the MAF560 Series particularly suitable for:

  • Hot factories
  • Workshops
  • Warehouses
  • Loading areas
  • Outdoor workspaces
  • Agricultural buildings
  • Livestock facilities
  • Greenhouses
  • Semi-open industrial environments

Unlike refrigeration-based air conditioning, evaporative cooling performance depends on ambient temperature, relative humidity, ventilation conditions and water evaporation rate.


Industrial Humidification

The atomization output can be adjusted from 0 to 20 L/h, allowing the equipment to provide additional moisture where environmental humidity needs to be increased.

Typical applications include:

  • Textile production
  • Printing facilities
  • Paper processing
  • Wood processing
  • Agricultural environments
  • Greenhouses
  • Livestock buildings
  • Concrete curing
  • Dust-sensitive production areas
  • Dry industrial environments

High-Volume Air Circulation

The fan can operate independently without atomization.

This allows the MAF560 Series to also function as a high-volume mobile circulation fan for:

  • Ventilation support
  • Worker cooling
  • Air movement
  • Heat removal
  • Local airflow improvement
  • Stagnant-air reduction

Maximum airflow reaches 14,000 m³/h on the high-airflow version.


Environmental Spraying

The centrifugal atomization system can also be used for selected environmental spraying applications when the liquid is compatible with the water tank, pump, pipelines, seals and atomization components.

Potential applications include:

  • Environmental treatment
  • Sanitation support
  • Compatible disinfection spraying
  • Odor-control spraying
  • Agricultural spraying
  • Dust suppression support

Important: Always verify chemical compatibility before introducing any liquid other than clean water.

Do not use corrosive, flammable, highly toxic or chemically incompatible liquids.


Key Features

Up to 14,000 m³/h High Airflow

The YTE-MAF560-H delivers up to 14,000 m³/h, helping move large volumes of air across industrial and semi-open spaces.


0–20 L/h Adjustable Atomization

Adjust the atomization output according to actual cooling, humidification or spraying requirements.

This allows the same equipment to work under different environmental conditions instead of operating at one fixed mist output.


Centrifugal Atomization System

The centrifugal atomizer converts water into fine droplets and introduces them directly into the airflow.

Advantages include:

  • Continuous atomization
  • Adjustable water output
  • Wide mist distribution
  • Integrated airflow and atomization
  • Suitable for industrial mobile applications

150–170 L Large Water Tank

A large-capacity water tank supports extended operation and reduces the frequency of manual refilling.

The system can also be equipped with a direct water supply float valve for continuous water replenishment where required.


Up to 120° Oscillation

The oscillating fan assembly distributes air and mist across a wider area.

This is particularly useful in:

  • Workshops
  • Production areas
  • Livestock buildings
  • Greenhouses
  • Loading zones
  • Open working areas

Mobile Heavy-Duty Design

The integrated wheeled frame allows the system to be moved between different work areas.

Instead of installing a fixed cooling or humidification system in every zone, one mobile unit can be repositioned according to operational requirements.


Independent Fan Operation

Atomization can be stopped while the fan continues operating.

This means the same machine can be used as:

Misting Fan

or

High-Volume Circulation Fan

depending on the operating condition.


Automatic Water Protection

The system is equipped with water protection to help prevent the pump from operating under insufficient-water conditions.


Leakage Protection

Power supply leakage protection is incorporated to improve electrical safety during operation.


Technical Specifications

Specification YTE-MAF560-H YTE-MAF560-E
Product Type Industrial Mobile Atomization Fan Industrial Mobile Atomization Fan
Version High-Airflow Energy-Efficient
Motor Configuration 4-Pole 6-Pole
Input Power 800 W 340 W
Motor Output Power 520 W 225 W
Rated Current 3.75 A 1.5 A
Motor Speed 1,400 rpm 930 rpm
Airflow 14,000 m³/h 8,500 m³/h
Voltage 220V / 50Hz 220V / 50Hz
Atomization Output 0–20 L/h, adjustable 0–20 L/h, adjustable
Water Tank Capacity 150–170 L 150–170 L
Recommended Coverage* Up to 350 m² Up to 250 m²
Oscillation Angle Up to 120° Up to 120°
Weight 44 kg 42 kg
Package Size 650 × 610 × 1560 mm 650 × 610 × 1560 mm
Water Supply Manual Filling / Optional Direct Water Supply Float Manual Filling / Optional Direct Water Supply Float
Fan-Only Operation Yes Yes
Atomization System Centrifugal Centrifugal
Mobility Wheeled Mobile Frame Wheeled Mobile Frame

*Coverage is a reference value only. Actual performance depends on ambient temperature, humidity, ventilation conditions, installation location, airflow obstruction and atomization settings.


Main Components

The YTE MAF560 Series consists of the following principal components:

  1. Fan Housing
  2. Oscillation Switch
  3. Locking Mechanism
  4. Caster Wheels
  5. Fan Blades
  6. Front Guard
  7. Rear Guard
  8. Centrifugal Atomizer
  9. Electric Motor
  10. Water Tank
  11. Water Tank Cover
  12. Water Pump with Water Protection
  13. Mobile Frame
  14. Handle

How It Works

Step 1 — Water Supply

Clean water is supplied from the integrated 150–170 L tank or through the optional direct water supply system.

↓

Step 2 — Centrifugal Atomization

Water is delivered to the centrifugal atomizer and converted into fine droplets.

↓

Step 3 — High-Volume Airflow

The fan produces up to 14,000 m³/h of airflow and carries the atomized water into the surrounding environment.

↓

Step 4 — Evaporation

Fine droplets evaporate into the surrounding air.

↓

Step 5 — Heat Absorption

During evaporation, water absorbs heat from the air.

↓

Result

Cooling + Humidification + Air Movement

The same airflow can also be used to distribute compatible environmental treatment liquids when appropriate.


Operating Modes

Fan Only

Air Circulation

The atomization system remains off while the fan provides high-volume airflow.

Suitable for:

  • Ventilation
  • Worker cooling
  • Air circulation
  • Heat removal

Fan + Low Atomization

Light Cooling / Light Humidification

Suitable when only a small amount of moisture is required.


Fan + Higher Atomization

Maximum Evaporative Cooling / Humidification

Suitable for hot and dry conditions where higher evaporation rates are possible.


Environmental Spraying Mode

Compatible liquids may be introduced for selected spraying applications after confirming material and chemical compatibility.


Typical Applications

Factories & Workshops

Suitable for high-temperature workshops and industrial working areas where conventional air conditioning may be impractical.

Applications include:

  • Worker cooling
  • Production-area cooling
  • Local air circulation
  • Heat removal

Warehouses & Logistics Centers

High-volume airflow helps improve air circulation in:

  • Warehouses
  • Loading docks
  • Distribution centers
  • Material handling areas

Textile Industry

Supports humidity control in dry production environments where inadequate humidity can contribute to:

  • Static electricity
  • Fiber dryness
  • Dust
  • Process instability

Printing & Paper Processing

Can provide additional moisture where dry air affects paper behavior or process conditions.


Concrete Curing

Adjustable atomization can provide moisture support during concrete curing applications.

The operating setting should be selected according to:

  • Curing requirements
  • Ambient temperature
  • Air movement
  • Surface moisture requirements

Agriculture & Greenhouses

Suitable for:

  • Greenhouses
  • Nurseries
  • Propagation areas
  • Agricultural production
  • General crop environments

Functions can include:

  • Cooling
  • Humidity support
  • Air circulation

Livestock & Poultry Facilities

High-temperature livestock environments may benefit from combined airflow and evaporative cooling.

Typical applications include:

  • Poultry houses
  • Dairy facilities
  • Pig farms
  • Livestock shelters

Actual cooling performance depends strongly on environmental humidity and ventilation conditions.


Outdoor & Semi-Open Areas

Suitable for:

  • Outdoor workplaces
  • Construction sites
  • Loading zones
  • Industrial yards
  • Event areas
  • Temporary workstations

Dust Suppression Support

Fine atomization can assist with airborne dust control in selected environments.

Dust-control performance depends on:

  • Droplet size
  • Dust particle characteristics
  • Air velocity
  • Spray volume
  • Installation position

Environmental Treatment & Sanitation

The atomization system may support selected environmental treatment or sanitation spraying applications using compatible approved liquids.

Chemical compatibility must always be verified before use.


Cooling Performance

The YTE MAF560 Series uses evaporative cooling, not compressor refrigeration.

Its cooling capacity therefore depends on environmental conditions.

Cooling performance is generally stronger when:

  • Ambient temperature is high
  • Relative humidity is low
  • Air exchange is sufficient
  • Mist can evaporate before reaching surrounding surfaces

Performance decreases as ambient relative humidity increases.

For applications requiring a guaranteed room temperature, such as maintaining an enclosed production room at 25°C, a refrigeration-based industrial air-conditioning system should be considered instead.


Atomization vs. Refrigeration Cooling

YTE MAF560 Industrial Air Conditioner
Evaporative cooling Compressor refrigeration
Uses water Uses refrigerant
Increases humidity Usually removes moisture
Best for open / semi-open environments Best for enclosed controlled spaces
High airflow Controlled refrigerated airflow
Low electrical consumption Higher electrical consumption
Mobile and flexible Usually larger system requirement
No refrigeration compressor Refrigeration compressor required

Why Choose the MAF560-H?

Choose YTE-MAF560-H when your priority is:

  • Maximum airflow
  • Wider coverage
  • Stronger worker cooling
  • Larger industrial areas
  • Greater air circulation
  • Higher heat-removal capability through airflow

Key performance:

14,000 m³/h · 1,400 rpm · 800 W


Why Choose the MAF560-E?

Choose YTE-MAF560-E when your priority is:

  • Lower electrical consumption
  • Lower-speed operation
  • Smaller operating zones
  • Continuous operation
  • Cooling and humidification with reduced power demand

Key performance:

8,500 m³/h · 930 rpm · 340 W


Optional Direct Water Supply

For long-duration applications, the machine can be equipped with a direct water supply float system.

When the tank water level falls, the float valve can automatically replenish the tank from an external clean-water supply.

This reduces manual refilling requirements during continuous operation.


Installation & Positioning Recommendations

For best performance:

  • Position the unit where airflow is not blocked.
  • Keep sufficient clearance around the air inlet.
  • Direct airflow toward the required cooling or humidification zone.
  • Allow atomized water sufficient distance to evaporate.
  • Avoid placing the machine too close to electrical equipment or moisture-sensitive products.
  • Increase ventilation when using high atomization output.
  • Adjust atomization according to ambient relative humidity.

For evaporative cooling applications, proper ventilation is important because accumulated humidity will reduce further evaporation.


Water Quality

Clean water is recommended.

Poor water quality may cause:

  • Mineral accumulation
  • Atomizer deposits
  • Pump contamination
  • Reduced atomization performance
  • Increased maintenance requirements

In areas with high water hardness, treated or softened water may improve long-term operating reliability.


Maintenance

Routine maintenance should include:

  • Cleaning the water tank
  • Checking the atomizer
  • Inspecting the water pump
  • Checking hoses and fittings
  • Cleaning fan guards
  • Inspecting fan blades
  • Checking caster wheels
  • Checking electrical cables
  • Removing mineral deposits where necessary

The tank should not be allowed to store stagnant water for extended periods.


Safety Notes

Do not operate the equipment:

  • With damaged electrical wiring
  • Near flammable gases
  • Near explosive materials
  • With incompatible chemicals
  • In environments beyond the electrical protection level of the equipment

Do not spray directly onto:

  • Electrical control cabinets
  • Unprotected electrical equipment
  • Sensitive electronics
  • Surfaces that cannot tolerate moisture

Disconnect the power supply before maintenance or cleaning.


Chemical Compatibility Notice

The standard YTE MAF560 Series is primarily designed for clean-water atomization.

For environmental spraying, sanitation or disinfection applications, users must verify that the selected liquid is compatible with:

  • Water tank
  • Water pump
  • Hoses
  • Seals
  • Metal components
  • Atomizer components

Do not assume that all disinfectants or chemical solutions are suitable.

For corrosive or chemically aggressive applications, contact YTE before use.

WHATSAPP CONSULTATION